首页 › 论坛 › BBS 利用報告はこちらへ › Cas ci-200 manual
- 您的话题内容不能为空。
-
作者帖子
-
Okkonen
游客.
.
Download / Read Online Cas ci-200 manual
.
.
..
Series, a family of digital indicators providing full featured versatility and dependability at an economical price. WeighSouth offers a wide Varity of Price Computing NTEP approved scales. Performance optimized by WP Rocket. Top element. Keep this manual in a place where product users can find out, after finish reading it. Warning Never disassemble, repair or retrofit the Ensure the power plug to be fully Ensure the grounding of the product. Poor grounding might cause failure or It might exclude the product from the Any instable connection might cause electric shock upon electric leak. Attention Check the weighing error anytime for Avoid any sudden shock to the product. Find a proper place to attach the rubber the accurate weighing. It might damage the product to fail the pad at the bottom of the indicator, Any use out of the allowed tolerance accurate weighing. How to Connect Serial Communication Devices . How to Connect an Auxiliary Display. How to Connect a Label Printer . Displaying the value of gross or net weight. Displaying the status value for the Set Mode and weight setup mode. LED Lamp LCD Status Display Descriptions. Some functions can be defined to the needs. The function set at F17 in the Set Mode will be operated. The function set at F18 in the Set Mode will be operated. Use it to check the remaining capacity of battery. Use it to correct any wrong input while entering data. LOAD CELL A port to connect load cell. It is a terminal for grounding to improve electric noises, which is connected to the grounding line upon any abnormalities in the product. How to Connect Load Cell Connect the load cell connector to the load cell port on the back of the indicator. How to connect the load cell to the connector. It refers to the calibration to set the displayed value to the actual weight in displaying weights. Zero Calibration Used key Display Descriptions UnLoAd Empty the load tray and press the setup key. Zeroing The current weight value is displayed. The current weight value is displayed. CAL Empty the load tray and press the setup key. Menu navigation Dual range function is not used. After the calibration mode is carried out, proceed to the following step. Connect the sealing wire as shown in the picture. Press the sealing wax as shown in the picture. How to Enter the Set Mode Turn on the power while pressing key at the indicator front to start the Set Mode. Or, Hold key for about 3 seconds to move from other mode to the convesion mode. AM Function Auto Power OFF Display Meaning Setting range. Function Setting vibration filter Display Meaning Setting range Vibration filter OFF F06. Compensation for the vibration value of 49. Function Weight Backup Function Display Meaning Setting range Weight backup is not used. As the backup state memorizes the initial status at zero for the weighing machine even during the blackout or when the power is turned off, the weight value is displayed if there is any weighing object in the weighing machine when the power is turned on. Function Set the front key input to be allowed. Display Meaning Setting range The front keys are unlocked. If it is set to 1, some function keys among the front keys cannot be used. Function Set the use of function key 1. Function Set the initial zero range Display Meaning Setting range F21. Function Function Set Device ID Display Meaning Setting range Device ID 00 F26. This function enables to use the unique indicator ID in the command mode. Serial Communication COM1 Function Function Set COM1 Baud Rate Display Meaning F28. Request Signal Output Signal Z CR Zero Point Key Received Data Return T CR Zero Point Key Received Data Return K G CR Gross Weight Key Received Data Return K N CR Net Weight Key Received Data Return. F32 4 F32 5 19200 bps F32 6 38400 bps F32 7. Print Function Function Set a printer to use Display Meaning Setting range F40 0 Not used. Net Weight Date, Time, Weighing No. The weight, count and percent cannot be printed at the same time. Display Meaning Setting range Not used. Display Meaning Setting range General functions are operated as the buzzer. F51 1 Buzzer ON when the checker function is OK. Other Functions Function Password Change Display Meaning. How to Enter the Test Mode Test mode starts when the power is turned on while pressing key in the front of the indicator. Press the number for the test menu as you wish. To enter the weighing mode during test, press key for a long time. Number Code Number Code Number Code Test 2. D conversion test Used key Display Descriptions The internal value for the current XXXXXX weight value is displayed. If the printer connection and the designation are done correctly, the following details will be shown in the printer. Battery test Used key Display Descriptions b 6. How to Enter the System Mode Load Descriptio Step Display Screen and Key Input Tray Press key for about 3 seconds in the weighing Empty mode. Initial Screen Descriptions Percent Mode. PCS MODE Sample Input Method Lo filexlib.
.
Cas ci-200 handleiding
Cas ci-200 manual lawn
Cas ci-200 owner guide
Cas ci-200 kezikonyv
Cas ci-200 manually -
作者帖子